TECHNICAL DATA

Item Code 3S-SMS-MB-M
Soiling Ratio 0% – 100%
Resolution 0,1%
Uncertainty ≤1%
Irradiance 0…1600 W/m²
Followed Standard IEC61724-1 (Annex C)
Data Output RS485 up to 38400 Baud
Communication Protocol Modbus RTU
Output Rate 1/s
Operating Temperature Range -40°C to +85°C
Operating Humidity Range 0 to 100%
Power Supply 12 to 30 V DC
Power Consumption 20 mA @ 24 V DC
Electrical Connection 3 m LIYYC11Y PUR Cable, UV and weather resistant
Galvanic Isolation 1000 V between power supply and RS485 Bus
IP Rating IP 65
Dimensions 244 mm x 108 mm x 42 mm (W x L x H)
Weight 500 g
Calibration Each sensor is calibrated under Class AAA Sun Similator as per IEC 60904-2 by using a reference cell calibrated by ISFH-Germany
Test Each sensor is tested under natural sunlight by using a calibrated reference cell from Fraunhofer ISE, Germany.)